All best sellers
Yilink LifePo4 Battery 4.8Kw 100A 48v Rack version 4U
  • Yilink LifePo4 Battery 4.8Kw 100A 48v Rack version 4U
  • Yilink LifePo4 Battery 4.8Kw 100A 48v Rack version 4U
  • Yilink LifePo4 Battery 4.8Kw 100A 48v Rack version 4U
  • Yilink LifePo4 Battery 4.8Kw 100A 48v Rack version 4U
  • Yilink LifePo4 Battery 4.8Kw 100A 48v Rack version 4U

Yilink LifePo4 Battery 4.8Kw 100A 48v Rack version 4U

YL-IPR48V100AEU
Rating 
€1,342.00
Tax included
Quantity

Description

Yilink LifePo4 Battery 4.8Kw 100A 48v Rack version 4U

Equipped with its own BMS, it can be used with any 48v inverter.
Possibility of connecting BMS communication cable with Voltronic inverters (all models equipped with BMS port) such as Axpert King, Vm III, Vm IV, Mks III, Mks IV, Axpert Max (all 48v models) and Max II

Battery pack Parameters

No.

Items

General Parameter

Remark

1

Combinations method

15S

2

Nominal voltage

48V

 

3

 

Rated Capacity

Typical

100Ah

Minimum

100Ah

4

Energy

4800Wh

5

Factory voltage

48~51V

mean Operation voltage

6

voltage at end of Discharge

37.5~42V

Discharge Cut-offs voltage

7

voltage at end of Charge

52.5~55.5V

Charge Cut-offs voltage

 

8

 

 

Standard charge

Constant Current 20A Constant voltage if it's No.7

0.02CA cut off

 

Charge time : Approx 5~6 h

9

 

Limiting current

20A

BMS extension limited (Charge current is

≥100A to open the current limits)

10

Standard discharge

Constant current 20A end voltage if it's NO.6

11

maximum continuous Charge Current

100A

50ºC≥T≥5ºC

12

maximum continuous Discharge Current

100A

55ºC≥T≥0ºC

 

 

 

13

 

 

Operation Temperatures Range

Charge:0~55

60±25 %R .H.

No matter what fashions the battery is in, ounces the temperatures is found to exceed the absolute temperatures range, stop charging or discharging immediately

 

 

D i s c h a r g e : - 2 0 ~ 6 0

 

 

14

 

 

Storage Temperatures Range

Less than 6 months: -10~35

 

60±25 %R .H.

at the shipment stay

Less than 3 months: -10~45

Less than 1 months: -20~55

15

Dimensions(W*D*H)

442*480*178mm

I n c l u d e ca s e _

16

net Weight

46Kg

I n c l u d e ca s e _

 

 

 

 

17

 

 

 

 

I n t e r n a l I m p e d a n c e

 

 

 

≤45mΩ _ _

I n t e r na l r e si s ta n c e me a s u r e d at t A C 1KH Z after 50% charge.

The measure must use the new batteries that within one week after shipment and cycles less than 5

times.

Battery Management System

Function

 

 

 

 

 

alarm

cell over charge voltage

cell charge low temperatures

cell over-discharge voltage

cell charge over temperatures

pack over charge voltage

cell discharge low temperatures

pack over-discharge voltage

cell discharge over temperatures

Over current charge

environment low temperatures

Over current discharge

environment over temperatures

Moses over temperatures

 

 

 

 

 

Protection

cell over charge voltage

cell charge over temperatures

cell over-discharge voltage

cell discharge low temperatures

pack over charge voltage

cell discharge over temperatures

pack over-discharge voltage

environment low temperatures

Over current charge

environment over temperatures

Over current discharge

Short circuit

Moses over temperatures

Fault

cell charge low temperatures

 

 

 

 

Others

cell balance function

Communicate function

Total capacity function

Storage history function

Current limiting function

Dry contact function

No.

Items

Description

1

+ Power terminal

Power cable terminals: one connect to equipment, the other

one paralleling to other battery module for capacity expanding

2

- Power terminal

3

LCDs screen

Display the battery's date

4

Power Switches

To turn ON/OFF while battery

5

Working indicator light

Display stay information

6

ALM alarm indicator light

Red-trouble-light hon

7

Capacity volume indicator

Display the battery's capacity

8

Reset key

Sleep /Activation /Reset

 

9

 

AD extension Dialer

4 ADD switches, to define different address code for each battery module when multiple modules are cascading, up to 15

addresses.

 

10

 

Dry Contact Terminal

1 / 2 N o r m a l y _ o p e n , c l o s e d d u r i ng _ f a u l t p r o t e c t i o n ;

3/4 normally open, closed when a low battery alarm

11

RS485

RJ45 Port,used to connect to the inverter's RS485 port

12

CAN

RJ45 Port,used to connect to the inverter's CAN port

 

13

 

RS232

RJ11 Port,used battery condition monitoring or manufacturer to

debugging or service

14/15

RS485

RJ45 Port,used communication in parallel

16

grounding point

Safety

Product Details
Yilink
YL-IPR48V100AEU
10 Items

Data sheet

Warranty
5 years
Reviews

Write your review

Yilink LifePo4 Battery 4.8Kw 100A 48v Rack version 4U

Yilink LifePo4 Battery 4.8Kw 100A 48v Rack version 4U

Write your review
12 other products in the same category:

Follow us on Facebook