Yilink LifePo4 Battery 4.8Kw 100A 48v Wall version
Equipped with its own BMS, it can be used with any 48v inverter.
Possibility of connecting BMS communication cable with Voltronic inverters (all models equipped with BMS port) such as Axpert King, Vm III, Vm IV, Mks III, Mks IV, Axpert Max (all 48v models) and Max II
No. | Items | General Parameter | Remark | |
1 | Combinations method | 15S | ||
2 | Nominal voltage | 48V | ||
3 |
Rated Capacity | Typical | 100Ah | |
Minimum | 100Ah | |||
4 | Energy | 4800Wh | ||
5 | Factory voltage | 48~51V | mean Operation voltage | |
6 | voltage at end of Discharge | 37.5~42V | Discharge Cut-offs voltage | |
7 | voltage at end of Charge | 52.5~55.5V | Charge Cut-offs voltage | |
8 |
Standard charge | Constant Current 20A Constant voltage if it's No.7 0.02CA cut off |
Charge time : Approx 5~6 h | |
9 |
Limiting current | 20A | BMS extension limited (Charge current is ≥100A to open the current limits) | |
10 | Standard discharge | Constant current : 20A end voltage if it's NO.6 | ||
11 | maximum continuous Charge Current | 100A | 50ºC≥T≥5ºC | |
12 | maximum continuous Discharge Current | 100A | 55ºC≥T≥0ºC | |
13 |
Operation Temperatures Range | Charge:0~55 ℃ | 60±25 %R .H. No matter what fashions the battery is in, ounces the temperatures is found to exceed the absolute temperatures range, stop charging or discharging immediately | |
D i s c h a r g e : - 2 0 ~ 6 0 ℃ | ||||
14 |
Storage Temperatures Range | Less than 6 months: -10~35 ℃ |
60±25 %R .H. at the shipment stay | |
Less than 3 months: -10~45 ℃ | ||||
Less than 1 months: -20~55 ℃ | ||||
15 | Dimensions(W*D*H) | 480*520*167mm | I n c l u d e ca s e _ | |
16 | net Weight | 52Kg | I n c l u d e ca s e _ | |
17 |
I n t e r n a l I m p e d a n c e |
≤40mΩ _ _ | I n t e r na l r e si s ta n c e me a s u r e d at t A C 1KH Z after 50% charge. The measure must use the new batteries that within one week after shipment and cycles less than 5 times. |
Function | ||
alarm | cell over charge voltage | cell charge low temperatures |
cell over-discharge voltage | cell charge over temperatures | |
pack over charge voltage | cell discharge low temperatures | |
pack over-discharge voltage | cell discharge over temperatures | |
Overcurrent charge | environment low temperatures | |
Overcurrent discharge | environment over temperatures | |
Moses over temperatures | ||
Protection | cell over charge voltage | cell charge over temperatures |
cell over-discharge voltage | cell discharge low temperatures | |
pack over charge voltage | cell discharge over temperatures | |
pack over-discharge voltage | environment low temperatures | |
Over current charge | environment over temperatures | |
Over current discharge | Short circuit | |
Moses over temperatures | Fault | |
cell charge low temperatures | ||
Others | cell balance function | |
Communicate function | ||
Total capacity function | ||
Storage history function | ||
Current limiting function | ||
Dry contact function |
No. | Items | Description |
1 | LCDs screen | Display the battery's date |
2 | Capacity volume indicator | Display the battery's capacity |
3 | ALM alarm indicator light | Red-trouble-light hon |
4 | Working indicator light | Display stay information |
5 | + Power terminal | Power cable terminals: one connect to equipment, the other one paralleling to other battery module for capacity expanding |
6 | - Power terminal | |
7 | Power Switches | To turn ON/OFF while battery |
8 | Reset key | Sleep /Activation /Reset |
9 |
AD extension Dialer | 4 ADD switches, to defined different address code for each battery module when multiple modules are cascading, up to 15 addresses. |
10 |
Dry Contact Terminal | 1 / 2 N o r m a l y _ o p e n , c l o s e d d u r i ng _ f a u l t p r o t e c t i o n ; 3/4 normally open, closed when a low battery alarm |
11 | RS485 | RJ45 Port,used to connect to the inverter's RS485 port |
12 | CAN | RJ45 Port,used to connect to the inverter's CAN port |
13 |
RS232 | RJ11 Port,used battery condition monitoring or manufacturer to debugging or service |
14 | RS485 | RJ45 Port,used communication in parallel |
15 | grounding point |
Reference: YL-IPR48V100AEU
Brand: Yilink
Reference: YL-IPR48V50AEU
Brand: Yilink
Reference: UP2500EU
Brand: PYLONTECH
Reference: BT-PY-CBKUS
Brand: PYLONTECH
Reference: YL-IPW48V150AEU
Brand: Yilink
Reference: LIOII4810EU
Brand: Voltronic
Reference: ESSII4810EUVL
Brand: Voltronic
Reference: WLF48V100AHEU
Brand: SOLARPOWER24
Reference: US3000CEU
Brand: PYLONTECH
Reference: ESSII4810810EU
Brand: Voltronic
Reference: ESSII4810510EU
Brand: Voltronic
Reference: UFO200AH48VEU
Brand: SOLARPOWER24
check_circle
check_circle