Voltronic Axpert MAX TWIN 11000-48 Inverter 11.0kw 48 volt Solar Inverter Photovoltaic Island
  • Voltronic Axpert MAX TWIN 11000-48 Inverter 11.0kw 48 volt Solar Inverter Photovoltaic Island

Voltronic Axpert MAX TWIN 11000-48 Inverter 11.0kw 48 volt Solar Inverter Photovoltaic Island

VL-AMT11K11K-48EU
Rating 
€1,259.04
Tax included
Quantity

Description

Voltronic Axpert MAX TWIN11000-48 Inverter 11kw 48 volt off grid island Photovoltaic inverter for off-grid hybrid island systems
• TWIN: 2 independent AC outputs which can be assigned different priorities
• Status indication with RGB lights
• Built-in Wi-Fi for mobile monitoring (Android / iOS app available)
• Support USB On-the-Go function
• Communication port reserved for BMS (RS485, CAN-BUS or RS232)
• Replaceable fan design for ease of maintenance
• Battery independent design
• Configurable AC / PV output usage priority and timer
• Selectable high power charge current
• Selectable input voltage range for home appliances and personal computers
• Communication with BMS battery Pylontech US2000/US3000, Yilink, SolarPower24
• Compatible with mains or generator input
• Built-in dust kit
• Optional DC output for DC fan, LED bulb, router and so on.
• Parallel operation with 6 units

TECHNICAL SPECIFICATIONS

Table 1 Line Mode Specifications

TEMPLATE

11KW

Input voltage waveform

Sinusoidal (AC mains or generator)

Rated input voltage

230Vac

Low voltage drop

170Vac±7V (UPS)

90Vac±7V (equipment)

Low Return Voltage Drop

180Vac±7V (UPS);

100Vac±7V (Equipment)

High voltage drop

280Vac±7V

High Return Voltage Drop

270Vac±7V

Max. AC input voltage

300Vac

Max. AC Input Current

60A

Max current outgoing by second port

40A

Rated input frequency

50Hz / 60Hz (Autodetect)

Low Frequency Drop

40±1Hz

Low Return Voltage Drop

42±1Hz

High Frequency Fall

65±1Hz

High Return Voltage Drop

63±1Hz

Output short circuit protection

Line Mode: RCD (70A)

Battery Mode: Electronic Circuits

Efficiency (Line Mode)

>95% (nominal load R, battery fully charged)

Duration of transfer

10ms typical (UPS);

20ms typical (equipment);

Output power reduction:

If the AC input voltage drops below 170V, the output power will be reduced.

 

Table 2 Inverter Mode Specifications

TEMPLATE

11KW

Rated output power

11000W

Output voltage waveform

Pure sine wave

Output voltage regulation

230Vac±5%

Output frequency

60Hz or 50Hz

Peak efficiency

93%

Overload protection

100ms@≥180%load;5s@≥120%load; 10s@105%~120% load

Overload capability

2* Rated power for 5 seconds

Low DC alarm voltage

 

@ load

46.0Vdc

@ 20% ≤ load

42.8Vdc

@ load ≥ 50%

40.4Vdc

Low DC Alarm Return Voltage

 

@ load

48.0Vdc

@ 20% ≤ load

44.8Vdc

@ load ≥ 50%

42.4Vdc

Low DC cutoff voltage

 

@ load

44.0Vdc

@ 20% ≤ load

40.8Vdc

@ load ≥ 50%

38.4Vdc

DC High Recovery Voltage

61Vdc

High DC cutoff voltage

63Vdc

DC voltage accuracy

+/-0.3V@ no load

THD extension

DC offset

100mV

Power limitation

If the battery voltage is lower than 55Vdc, the output power will be reduced. If the connected load is greater than this reduced power, the AC output voltage will decrease until the output power reduces to this reduced power. The minimum AC output voltage is the output voltage setting - 10V.

 

 

 

 

 

Table 3 Charge Mode Specifications

AC Grid Charge Mode

TEMPLATE

11KW

Charging current (UPS)

@Nominal input voltage

150A

Bulk charge voltage

Lead-acid battery

58.4Vdc

AGM/Gel battery

56.4Vdc

Charge float voltage

54Vdc

Overload protection

63Vdc

Charging algorithm

3-Step

Charge curve

Solar entrance

TEMPLATE

11KW

Nominal power

11000W

Max. PV Array Open Circuit Voltage

500Vdc

PV array MPPT voltage range

90Vdc~450Vdc

Max. Input current

27A x 2 (MAX 40A)

Max. Charging current

150A

Starting voltage

80V +/- 5Vdc

Power limitation

 

 

 

Table 4 General specifications

TEMPLATE

11KW

Security Certification

THERE IS

Operating temperature range

- 10°C + 50°C

Storage temperature

-15°C~60°C

Humidity

5 - 95% relative humidity (non-condensing)

Dimensions

(P*L*H), mm

147.4 x 432.5 x 553.6

Net weight, kg

18.4

 

Table 5 Parallel specifications

Max. no. in parallel

6

Circulating current under no-load conditions

Max. 2A

Power imbalance ratio

Parallel communication

CAN

Transfer time in parallel mode

Max. 50ms

Parallel Kit

YES

Note: Parallel function will be disabled if only PV power is available

Product Details
VOLTRONIC
VL-AMT11K11K-48EU
10 Items

Data sheet

New / Used
New
Warranty
24 Month
Cod. Art.
Attachments
Download
Reviews

Write your review

Voltronic Axpert MAX TWIN 11000-48 Inverter 11.0kw 48 volt Solar Inverter Photovoltaic Island

Voltronic Axpert MAX TWIN 11000-48 Inverter 11.0kw 48 volt Solar Inverter Photovoltaic Island

Write your review
16 other products in the same category:

Follow us on Facebook